Traffic Regulation Module
Function
- Power supply 12V or 24V onto 2 power elements
+Bat (top; max. 90 A) and +IGN (+APC/bottom; max. 35 A)
- Relay bases for 4 Micro relays and 4 Mini relays
- 2 x 9-way relay bases for fl asher unit, wiper,
programmable relays etc.
- 1 pluggable bridge for relay combinations
- 18 ATO fuseholders (up to 15A)
- Cable harness connector on the rear side of the module
(JPT/MCP compatible, 3 row connectors)
- On-board fuse-tester
Options
- Fly wheel diode (SM4007) in parallel of relay coil
- Fuses or circuit breakers
- Frame for modular board assembly
- Standard relays
Applications
- All the mandatory and common functions for off-highway and on-highway vehicles such as lighting,
fl asher, horn, wash/wipe, beacon, radio, clock, HVAC, accessories etc.
Technical Data
- Temperature range: -40°C bis +80°C
- Max. supply current: +BAT/30 (Power elements M5): Input on 1 Power element: Max. 70A by 80°C ambient. Input on 2 Power elements: Max. 110A by 65°C ambient; Max. 90A by 80°C ambient.
- Max. supply current: +IGN(+APC)/15 (Power element M5): Max. 35A by 65°C ambient; Max. 25A by 80°C ambient
- Output connection: JPT/MCP compatible 3 row, 3 colors coded
(1x9 pins, 1x12 pins, 2x15 pins, 1x18 pins) connectors
- Input connection (power stud): Power element M5 female 16 pins; Max. mounting torque: 2,2 Nm
- Recommended wire section: Current < 15A: 7,5A per mm2; Current > 15A: 5A per mm2