PROP CAN

Description

The proportional valve controller with CAN Bus serves to regulate the flow rates of a proportional valve. It can be used for many hydraulic applications. CAN high- or low-speed (alternatively RS485) Bus can be used to communicate with further systems and offer an easy integration in existing systems.

Function

The micro controller's current control is direct proportional to the set-point 0 - 10 Volt or 0 - 20 mA. Contolling and read/write of all values by CAN Bus possible. Fluctuations in supply voltage and temperature are compensated. Thereby a constant flow rate is ensured. In order to avoid a determining of the valve, a Dither frequency (overlaid rectangle with smaller frequency) can be adjusted. For different housing please see in the chapter housing and baseplates.

Technical data

Label   Value
Operating voltage   9-30 V
Quiescent current   <250 µA (stand by), 30 mA (idle)
continuous current   max. 3 A
Ingress protection   IP53

Design

Connection diagram

Order Table

Label   Ausführung   Housing   Ordering Nr.
Proportionalverstärker CAN 9-30 V   Desired voltage/ Current with CAN bus   S1/G2/E   1.108.310.00E

Accessoires

Label   Ordering Nr.
Programming tool MRS Developers Studio   1.100.100.00E
Flat pin Socket   1.017.002.00E
Faston terminal 6,3mm 1,5-2,5mm2   103064E
Faston terminal 6,3 mm 1mm2   102355E
Faston terminal 2,8mm 0,5-1,0mm2   105292E
bracket for housing   1.017.080.00E

Download

Productinformation as PDF